The story of our success starts here. Emiltrafo was founded in 1980 as a spin off of a leading company in the world for the construction of automatic machines, industry characterized by increasingly sophisticated new technologies, and the need to find creative solutions.
Because Emiltrafo can answer these challenges we quickly become trusted supplier for many companies of transformers for automatic machines, establishing relationships that last for more than 35 years. Our strength lies in the production of transformers and autotransformers custom, comply with the standard CEI EN 61558-2 , and able to guarantee an absolute reliability and safety against direct and indirect contacts.
Single-phase transformer
Power: from 50 to 5000 VA
Primary voltage: more input voltages up to 1000 V
Secondary voltages: More voltage up to 1000 V
rules:
CEI 96-2
CEI 96-8
CEI 96-9
EN 61558-2
EN 61558-4
EN 61558-6
Insulation voltages up to 6 kV
Frequency: 50/60 Hz
Protection degree IP20
Insulation class: I
Thermal class materials: F or H (on request)
Maximum ambient temperature 40 ° C
Single-phase transformer columns
Power: from 5000 to 13000 VA
Primary voltage: more input voltages up to 1000 V
Secondary voltages: More voltage up to 1000 V
rules:
CEI 96-2
CEI 96-8
CEI 96-9
EN 61558 - 2 - 1
EN 61 558 - 2 - 4
Insulation voltages up to 6 kV
Frequency: 50/60 Hz
Protection degree IP20
Insulation class: I
Thermal class materials: F or H (on request)
Maximum ambient temperature 40 ° C
Three-phase transformer
Group: your choice, for both the primary, that for the secondary
Power: from 1000 to 100,000 VA
Primary voltage: more input voltages up to 1000 V
Secondary voltages: More voltage up to 1000 V
rules:
CEI 96-3
CEI 96-8
EN 61558-1
EN 61558 - 2 - 1
EN 61558 - 2-4
Insulation voltages up to 6 kV
Frequency: 50/60 Hz
Protection degree IP20
Insulation class: I
Thermal class materials: F or H (on request)
Maximum ambient temperature 40 ° C
Phase power supply
Power: 50 VA to 5000 VA
Primary voltage: more input voltages up to 1000 V
Secondary voltages: More voltages up to 48 V
rules:
Insulation voltages up to 8 kV
Frequency: 50/60 Hz
Protection degree IP20
Insulation class: I
Thermal class materials: F or H (your choice)
Maximum ambient temperature 40 ° C
rectifier
switch
fuse holder
Three-phase power supply
Group: your choice, for both the primary, that for the secondary
Power: from 1000 to 50000 VA
Primary voltage: more input voltages up to 1000 V
Secondary voltages: More voltages up to 48 V
rules:
Insulation voltages up to 8 kV
Frequency: 50/60 Hz
Protection degree IP20
Insulation class: I
Thermal class materials: F or H (your choice)
Maximum ambient temperature 40 ° C
rectifier
switch
fuse holder
Single-phase autotransformer
Power: up to 25000 VA
Primary voltage: more voltages up to 1000 V
rules:
CEI 96-3
CEI 96-13
EN 61558-1
EN 61558 - 2 - 13
Insulation voltages up to 6 kV
Frequency: 50/60 Hz
Protection degree IP20
Insulation class: I
Thermal class materials: F or H (on request)
Maximum ambient temperature 40 ° C
Three-phase autotransformer
Power: up to 150000 VA
Primary voltage: more voltages up to 1000 V
rules:
CEI 96-3
CEI 96-13
EN 61558-1
EN 61558 - 2 - 13
Insulation voltages up to 6 kV
Frequency: 50/60 Hz
Protection degree IP20
Insulation class: I
Thermal class materials: F or H (on request)
Maximum ambient temperature 40 ° C
Toroidal transformers
Power: up to 1500 VA
Primary voltage: more input voltages up to 1000 V
Secondary voltages: More voltage up to 1000 V
rules:
Insulation voltages up to 6 kV
Frequency: 50/60 Hz
Protection degree IP00
Insulation class: I
Thermal class materials: F or H (on request)
Maximum ambient temperature 40 ° C
Transformer Threephase-singlephase
Power: up to 50000 VA
Primary voltage: more input voltages up to 1000 V
Secondary voltages: More voltage up to 1000 V
rules:
Insulation voltages up to 6 kV
Frequency: 50/60 Hz
Protection degree IP20
Insulation class: I
Thermal class materials: F or H (on request)
Maximum ambient temperature 40 ° C
Single phase chokes
Used for switching, power factor correction, filter
Inductance up to 15 mH
Current up to 200 A
rules:
CEI 14-5
IEC 60076-6
EN 61558 - 2 - 20
Insulation voltages up to 6 kV
Frequency: 50/60 Hz
Protection degree IP00
Insulation class: I
Thermal class materials: F or H (on request)
Maximum ambient temperature 40 ° C
Three phase inductances
Used for switching, power factor correction, filter
Inductance up to 25 mH
Current up to 300 A
rules:
CEI 14-5
IEC 60076-6
EN 61558 - 2 - 20
Insulation voltages up to 6 kV
Frequency: 50/60 Hz
Protection degree IP00
Insulation class: I
Thermal class materials: F or H (on request)
Maximum ambient temperature 40 ° C